Skip to main content
. 2020 Nov 27;156(1):7–12. doi: 10.1016/j.medcle.2020.08.001

Table 3.

Increase in respiratory function parameters, with respect to the first day of follow-up, in patients treated with glucocorticoids and paired controls.

Glucocorticoids Control p
Saturation increment
 48 h 0.20 (n = 25) 0.65 (n = 25) 0.507
 72 h 0.67 (n = 21) 0.46 (n = 21) 0.813
 96 h 0.64 (n = 20) 0.52 (n = 20) 0.904



FiO2 increment
 48 h 3.67 (n = 25) −2.87 (n = 25) 0.149
 72 h 2.65 (n = 24) −0.98 (n = 21) 0.587
 96 h 2.90 (n = 20) −2.98 (n = 20) 0.403



SF increment
 48 h −0.04 (n = 25) 0.37 (n = 25) 0.095
 72 h 0.01 (n = 20) 0.28 (n = 21) 0.351
 96 h 0.13 (n = 20) 0.43 (n = 17) 0.359

FiO2: inspired fraction of oxygen; SF: saturation/inspired fraction of Oxygen.