Algorithm performance on a case and lesion level.

Parameter Sensitivity (%) Specificity (%) PPV (%) NPV (%) Kappa k
Case level 87 50 87 50 0.42
Lesion level
PI-RADS category 3 43 / / / /
PI-RADS category 4 73 / / / /
PI-RADS category 5 100 / / / /
Combined PI-RADS category 4 and 5 78 / / / /