Skip to main content
. 2020 Nov 11;10(11):334. doi: 10.3390/membranes10110334

Table 8.

Main physicochemical properties of feed (FD) and permeate (PR) samples collected during the RO test with “aged” OMW2-CA.

VCR P
(bar)
pH Conductivity (µs/cm) COD (mg/L) Phenols (mg/L)
FD PR FD PR R (%) FD PR R (%) FD PR R (%)
1.00 30 5.91 4.82 13,500 117.4 99.13 40,200 2050 94.90 1025 5.2 99.49
1.14 30 5.87 4.84 14,200 135.2 99.05 44,500 2120 95.24
1.33 30 5.93 4.85 15,300 198.7 98.70 55,450 2290 95.87
1.60 30 5.94 4.87 16,450 240.1 98.54 67,800 2370 96.50
2.00 30 5.89 4.83 17,930 303.8 98.31 84,300 3540 95.80 2320 11.0 99.53
2.67 30 5.93 4.90 19,800 318.4 98.39 98,650 5900 94.02