Adjusted radii (r), equivalent square side lengths (lsq), and mean laser beam energies per 1 mm2 of cut area (Ep) for four tree species and four laser settings.

Trial Parameter Birch Poplar Oak Pine
P1 Adjusted radius r (mm) 8.8 10.5 10.9 9.6
N = 1000 W Square side length lsq (mm) 15.6 18.5 19.2 17.1
vp = 1000 mm·min−1 Laser beam energy Ep (J∙mm−2) 3.85 3.24 3.12 3.51
P3 Adjusted radius r (mm) 10.5 12.4 11.7 12.7
N = 500 W Square side length lsq (mm) 18.6 21.9 20.7 22.6
vp = 500 mm·min−1 Laser beam energy Ep (J∙mm−2) 3.22 2.74 2.90 2.65
P7 Adjusted radius r (mm) 24.0 19.3 18.4 20.7
N = 1000 W Square side length lsq (mm) 42.6 34.3 32.7 36.7
vp = 300 mm·min−1 Laser beam energy Ep (J∙mm−2) 4.69 5.83 6.12 5.45
P8 Adjusted radius r (mm) 35.1 32.9 35.9 31.2
N = 2000 W Square side length lsq (mm) 62.1 58.2 63.6 55.2
vp = 300 mm·min−1 Laser beam energy Ep (J∙mm−2) 6.44 6.87 6.29 7.24