Skip to main content
. 2020 Nov 22;12(11):3474. doi: 10.3390/cancers12113474

Table 4.

Anastomotic leak types and severity of postoperative complications among patients that developed an anastomotic leak. Stapler sizes of 25 and 28 mm were analyzed separately, and p-values for statistical comparison of both groups were calculated. Percentages were calculated as percentage from the cohort that developed an anastomotic leak.

25 mm Stapler 28 mm Stapler
n/Median (%)/Range n/Median (%)/Range p-Value
Total 33 (100) 45 (100) -
Type I 0 (0) 1 (2.2) 1
Type II 24 (72.7) 35 (77.8) 0.79
Type III 9 (27.3) 9 (20) 0.5876
Clavien–Dindo Classification
CD IIIa 14 (42.4) 21 (46.7) 0.8188
CD IIIb 4 (12.1) 6 (13.3) 1
CD IVa 9 (27.3) 9 (20) 0.5876
CD IVb 3 (9.1) 6 (13.3) 0.7259
CD V 3 (9.1) 3 (6.7) 0.6937
CD ≥ IV 15 (45.5) 18 (40) 0.6502
Length of Stay
LOS 36 16–112 30 13–99 0.3118