Volume, V100, V90, V70, V50, and V20 of planning target volume for left and right breast GRID plans.

Left case # Volume (cc) V100 (%) V90 (%) V50 (%) V20 (%)
Left breast
L1 432 1.21% 8.54% 68.23% 99.63%
L2 354 2.42% 10.40% 68.12% 99.01%
L3 1778 0.19% 1.91% 64.06% 99.77%
L4 556 2.29% 9.69% 68.73% 99.26%
L5 954 0.23% 4.36% 65.16% 99.34%
L6 891 0.21% 3.86% 63.95% 98.32%
Average 828 1.09% 6.46% 66.38% 99.22%
Right case # Right breast
R1 746 0.44% 6.45% 66.90% 99.68%
R2 1045 1.92% 8.88% 70.93% 99.58%
R3 562 2.11% 9.11% 68.93% 99.87%
R4 1173 1.00% 5.86% 68.06% 99.73%
R5 724 2.76% 10.61% 69.52% 99.44%
R6 553 1.21% 8.08% 69.30% 99.42%
Average 801 1.57% 8.17% 68.94% 99.62%

V100, V90, V50, and V20 represent the percentage of PTV volume covered by 100%, 90%, 50%, and 20% of prescription dose, respectively.