Skip to main content
. 2020 Nov 30;15(11):e0242720. doi: 10.1371/journal.pone.0242720

Table 4. Distances moved in meter per hour on the contaminated (pest; 10% or 100% of the of the maximum recommended field rate (FRmax); dpest) and uncontaminated (clean; dclean) side of an arena and results from two-sided Wilcoxon signed-rank tests that were used to compare dpest and dclean.

Formulation % of FRmax Side Distance moved (m/h) Wilcoxon-Test -
clean vs. pest
Median IQR Range Mean V p p adj.
Folpan® 500 SC 100 Clean 0.55 0.40–0.84 0.15–1.23 0.63 0 < 0.001 < 0.001
Pest 2.81 1.26–4.01 0.48–7.28 3.01
Folpan® 500 SC 10 Clean 0.81 0.49–2.30 0.18–5.06 1.58 58 0.632 0.701
Pest 1.19 0.91–2.27 0.38–6.68 1.90
Folpan® 80 WDG 100 Clean 1.69 0.84–2.48 0.30–4.85 198 72 0.860 0.860
Pest 1.67 0.89–2.42 0.26–5.02 1.94
Folpan® 80 WDG 10 Clean 1.35 0.80–1.75 0.53–6.42 1.70 70 0.934 0.782
Pest 1.25 0.87–1.83 0.30–4.93 1.66
Funguran® progress 100 Clean 0.98 0.69–1.99 0.27–4.27 1.43 64 0.860 0.860
Pest 0.77 0.54–2.71 0.26–5.26 1.56
SpinTorTM 100 Clean 1.36 0.94–2.63 0.30–4.92 1.85 52 0.433 0.606
Pest 1.39 0.81–5.14 0.28–5.97 2.53
Taifun® forte 100 Clean 0.93 0.79–1.21 0.30–2.61 1.11 24 0.021 0.050
Pest 2.33 0.84–3.35 0.47–3.98 2.21
Taifun® forte 10 Clean 1.14 0.73–2.39 0.41–8.20 1.91 66 0.934 0.782
Pest 1.65 0.74–2.44 0.48–4.20 1.74
Vivando® 100 Clean 0.63 0.31–1.04 0.07–4.19 0.89 17 0.006 0.022
Pest 1.44 0.94–3.20 0.37–6.75 2.37
Vivando® 10 Clean 2.37 0.80–3.11 0.47–5.11 2.20 86 0.376 0.751
Pest 1.32 0.70–2.47 0.28–3.97 1.63
Wettable Sulphur Stulln 100 Clean 0.94 0.72–1.94 0.43–3.96 1.53 31 0.058 0.101
Pest 2.24 1.12–3.91 0.53–4.61 2.46

P-values from tests with the same concentration were adjusted using the false discovery rate. Significant values are presented in bold. N = 16 per choice-test.