Skip to main content
. 2020 Nov 30;9:e59018. doi: 10.7554/eLife.59018

Table 2. CryoEM data collection and refinement statistics.

Data collection
Electron microscope Titan Krios G3
Camera Falcon 3EC
Voltage (kV) 300
Nominal magnification 75,000
Calibrated physical pixel size (Å) 1.06
Total exposure (e- /Å2) 42.7
Number of frames 30
Image processing
Motion correction software cryoSPARCv2
CTF estimation software cryoSPARCv2
Particle selection software cryoSPARCv2
3D map classification and refinement software cryoSPARCv2
Micrographs used 2080
Particles selected 669,223
Global resolution (Å) 3.2
Particles contributing to final map 165,747
Model building
Modeling software Coot, phenix.real_space_refine
Number of residues built 3085
RMS (bonds) 0.002
RMS (angles) 0.56
Ramachandran favored (%) 95.8
Rotamer outliers (%) 0.5
Clashscore 6.27
MolProbity score 1.63
EMRinger score 2.54