Skip to main content
. Author manuscript; available in PMC: 2020 Dec 2.
Published in final edited form as: Prog Brain Res. 2011;194:145–165. doi: 10.1016/B978-0-444-53815-4.00010-8

Table 2.

Summary of microstimulation sessions

Feline Figure label (Fig. 5a or c) Date Description Stimulus parameters Amplitudes Electrodes
3 1 14/Aug/2009 All-electrode (EMG efficacy test) 5 trains, 50 pulses 5–50 μA in steps of 5 μA All
3 2 29/Aug/2009 All-electrode (EMG efficacy test) 5 trains, 50 pulses 5–35 μA, steps of 1-μA 43,78,84
3 3 01/Sep/2009
02/Sep/2009
All-electrode stimulation 2 rounds, 5 trains, 25 pulses 20/30, 30/35 μA All
3 4 07/Sep/2009 Test of parallel stimulation 5 trains, 25 pulses 25 μA Distributed pattern of 72 electrodes
3 5 14/Sep/2009 All-electrode stimulation 5 trains, 25 pulses 20–35 μA in steps of 5 μA All
3 6 30/Oct/2009 All-electrode (EMG efficacy test) 10 trains, 25 pulses 20–40 μA in steps of 5 μA All
3 7 31/Oct/2009–09/Nov/2009 15/20 μA on seven electrodes 100 trains of 25 pulses 15/20 μA 88,89,90,91/79,80,81
3 15/20 μA (Teal bars) 11/Oct/2009–03/Dec/2009 (23 sessions) 15/20 μA paradigm 200 trains (two rounds), 25 pulses 15 or 20 μA 20 μA—Electrodes 79,80,81 15 μA—Electrodes
26,28,29,31,39,40,41,43,89,90,91,92
3 8 04/Dec/2009 All-electrode (EMG efficacy test) 5 trains of 25 pulses 20–40 μA in steps of 5 μA All
3 20/25/30/25 μA (Blue bars) 05/Dec/2009–13/Jan/2009 (20 sessions) 20/25/30/25 μA paradigm 200/electrode (two rounds), 25 pulses 20, 25, 30, or 35 μA 20 μA—Electrodes 39,40,41,43
25 μA—Electrodes 79,80,81
30 μA—Electrodes 89,90,91,92
35 μA—Electrodes 26,28,29,31
3 9 14/Jan/2010 All-electrode (EMG efficacy test) 5 trains of 25 pulses 100 μA All
4 1 17/Sep/2010 All-electrode (EMG efficacy test) 5 trains of 25 pulses 5–50 μA in steps of 5 μA All
4 2 28/Sep/2010 Test for feline response 5 trains of 25 pulses 5–50 μA in steps of 5 μA All
4 3 01/Oct/2010 All-electrode (EMG efficacy test) 5 trains of 25 pulses 50–100 μA in steps of 10 μA All
4 4 28/Oct/2010 All-electrode (EMG efficacy test) 5 trains of 25 pulses 20–60 μA in steps of 10 μA All
4 5–7 24/Nov/2010–30/Nov/2010 25 μA paradigm 100 trains of 25 pulses 25 μA 1,10,11,32,33,42,43,66,67,75,76,79,80,88,89
4 8 01/Dec/2010 All-electrode (EMG efficacy test) 5 trains of 25 pulses 40–100 μA in steps of 10 μA All
4 9 22/Dec/2010 All-electrode (EMG efficacy test) 5 trains of 25 pulses 50–100 μA in steps of 10 μA All

Microstimulation was applied to Felines 3 and 4 according to several different stimulus paradigms depending on the goals of microstimulation, for example, to evaluate efficacy or to determine the effects of periodic stimulation on device functionality.