Skip to main content
. 2020 Dec 3;20:919. doi: 10.1186/s12879-020-05600-8

Table 1.

German centres with CD diagnostics for routine patient care during 2000–2018

Center City Type of test Test availability (years) Number of retrieved tests Data availability (years)
Institute of Tropical Medicine and International Health, Charité – Universitätsmedizin in Berlin Berlin in-house IFT 2000–2010 204 2002–2018
in-house ELISA 2000–2018 830
Institute of Medical Microbiology, Immunology and Parasitology, University Hospital Bonn Bonn in-house IFT 2000–2010 201 2004–2018
commercial ELISA 2011–2018 190
commercial RDT 2000–2010 116
Bernhard Nocht Institute for Tropical Medicine Hamburg in-house IFT 2000–2018 2641 2000–2018a
in-house ELISA 2000–2018 2654
PCRb 2000–2018 200

Division of Infectious Diseases and Tropical Medicine,

University Hospital, LMU Munich

Munich in-house IFT 2000–2018 1670 2000–2018
in-house ELISA 2000–2018 1668
PCRb 2013–2018 35
Institute of Tropical Medicine, Medical Department, University Hospital Tübingen Tuebingen in-house IFT 2009–2018 319 2009–2018
Total 10,728

CD Chagas disease, ELISA Enzyme-linked immuno-sorbent assay, IFT Immunofluorescence test, PCR Polymerase chain reaction, RDT Rapid diagnostic test

aIndividual positive tests 2000–2018 and negative tests 2010–2018 could be retrieved

bHamburg offered a conventional PCR that was followed up by sequencing of the PCR product if positive, whereas Munich performed a conventional PCR that was followed up with an independent commercially available qPCR if positive (for details please see Supplement S2)