Table 1.

Comparison of Monaco-generated and RayStation-generated plans

Variable MRL_LS RS_LS MRL_TS RS_TS
GTV
D95%, cGy 2402.1 2485.0 2348.8 2437.0
Minimum dose, cGy 2277.5 2321.0 2186.5 2175.0
Maximum dose, cGy 2729.3 2759.0 2651.8 2737.0
Conformity index 0.6 0.4 0.7 0.4
Homogeneity index 1.1 1.1 1.1 1.1
R50 25.9 27.9 28.1 24.9
CTV
D95%, cGy 1600.3 1601.0 1602.8 1600.0
Conformity index 0.8 0.8 0.9 0.8
Homogeneity index 1.7 1.7 1.7 1.7
Gradient index 3.7 3.8 3.4 3.4
R50 4.09 4.28 4.09 3.78
Spinal cord
Maximum dose, cGy 1042.4 1065.0 1109.3 1032.0
V10Gy, cm3 0.01 0.01 0.059 0.0
Beam-on time, minutes 13.0 8.1 12.7 7.5
Monitor units 5517.4 4869.3 5390.3 4522.6

MRL_LS, Monaco-generated lumbar spine plan; RS_LS, RayStation-generated lumbar spine plan; MRL_TS, Monaco-generated thoracic spine plan; RS_TS, RayStation-generated thoracic spine plan; GTV, gross tumor volume; CTV, clinical target volume