Comparison of measurements obtained by TrueBeam and MRL plans

Variable Dmean, cGy
Lumbar spine Thoracic spine
GTV Spinal cord GTV Spinal cord
RayStation
Measurement 2605.2 ± 17.4 514.3 ± 2.7 2595.5 ± 9.6 470.4 ± 3.4
Original plan 2641.0 505.0 2664.0 440.0
% difference −1.4 1.8 −2.6 6.9
Monaco
Measurement 2702.9 ± 113.9 601.8 ± 22.9 2684 ± 14.4 884.6 ± 37.4
Adapted plan 2671.3 ± 19.6 605.6 ± 15.6 2602.3 ± 5.8 851.3 ± 39.6
Original plan 2644.5 562.8 2595.5 788.5
% difference 1.2 -0.6 3.1 3.9

% difference = (Measurement – (Adapted plan)) × 100 /Adapted plan