Skip to main content
. 2020 Dec 2;6(6):1765–1776. doi: 10.1016/j.bioactmat.2020.11.026

Table 1.

Ecorr and Icorr values calculated from the potentiodynamic polarization curves of Ca–P, Sr–P coated and uncoated Mg–Sr alloy in Hank's solution, by extrapolating the Tafel region.

Materials Ecorr (V) Icorr (μA/cm2) Vcorr (mm/y)
Ca–P coating −1.52 1.41 0.032
Sr–P coating −1.59 2.46 0.057
Mg–Sr alloy −1.60 3.68 0.084