Table 4.

Accuracy of the two general dentists with and without the multilayer imaging program

Observer 1 Observer 2
Without program
(95% CI)
With program
(95% CI)
p-value Without program
(95% CI)
With program
(95% CI)
p-value
Area under the ROC curve 0.792
(0.738–0.846)
0.923
(0.885–0.960)
<0.001* 0.833
(0.782–0.883)
0.862
(0.818–0.906)
0.148
Sensitivity 0.793
(0.666–0.888)
0.914
(0.810–0971)
0.828
(0.706–0.714)
0.879
(0.767–0.950)
Specificity 0.790
(0.762–0.817)
0.931
(0.713–0.947)
0.838
(0.812–0.862)
0.845
(0.819–0.868)
PPV 0.196
(0.169–0.226)
0.461
(0.399–0.524)
0.247
(0.214–0.238)
0.267
(0.233–0.304)
NPV 0.983
(0.973–0.990)
0.994
(0.986–0.997)
0.987
(0.977–0.993)
0.991
(0.982–0.995)

ROC, receiver operating characteristic; PPV, positive predictive value; NPV, negative predictive value; CI, confidence interval

*p<0.05.