Skip to main content
. 2020 Dec 3;24:2331216520973539. doi: 10.1177/2331216520973539

Table 2.

Results of the test battery (BEAR3 dataset) presented as the 5th, 25th, 50th and 75th and 95th percentiles.

Variables 5th 25th 50th 75th 95th Unit
AUDLF 6.08 18.33 25 35 45.33 dB HL
AUDHF 22.41 45.83 54.16 62.08 70.58 dB HL
FLFT 4.12 6.27 7.94 10.24 12.2 kHz
HTLLF 2.45 16.25 24.16 36.67 48.96 dB HL
HTLHF 16.87 35.62 48.75 57.91 71.29 dB HL
MCLLF 65.54 75.62 79.79 84.37 91.71 dB HL
MCLHF 66.37 74.37 80.21 88.95 98.21 dB HL
DynRLF 55.12 64.37 77.5 86.87 98.29 dB
DynRHF 34.12 41.25 50.2 61.66 82.79 dB
SlopeLF 0.3 0.35 0.41 0.55 0.67 CU/dB HL
SlopeHF 0.38 0.56 0.75 0.91 1.52 CU/dB HL
SRTQ 15.57 31.74 42.06 50.67 60.14 dB HL
maxDS 86.58 94.28 97 98.77 100 % Corr.
SRTN –0.87 0.71 1.76 3.86 8.73 dB SNR
SScore4dB 25 52.5 72.5 84.38 92.5 % Corr.
IPDfmax 0.25 0.53 0.69 0.93 1.1 kHz
BP20 15 71.25 95 100 100 % Corr.
BMR 7.5 12.79 15.75 17.62 22.25 dB
sSTM8 –0.4 0.49 2.36 3.07 3.07 d’
fSTM8 –10.71 –7.9 –5.68 –1.5 0 dB 20log(m)
TiNLF 67.57 69.93 71.56 73.56 76.42 dB HL
TiNHF 70.03 72.12 73.93 75.87 79.26 dB HL
TMRLF 3.32 6.81 7.92 10.12 12 dB
TMRHF 0.67 5.85 8.83 10.78 15.01 dB
SMRLF 11.87 17.31 21.06 23.19 25.37 dB
SMRHF 4.21 12.68 21.62 27.21 33.56 dB

Note. AUDLF = pure-tone average at low frequencies; AUDHF = pure-tone average at high frequencies; FLFT = fixed-level frequency threshold; HTLLF = hearing threshold levels averaged for low frequency; HTLHF = hearing threshold levels averaged for high frequency; MCLLF =most comfortable level averaged for low frequency; MCLHF = most comfortable level averaged for high frequency; DynRLF = dynamic range for low frequency; DynRHF = dynamic range for high frequency; maxDS = maximum word recognition score; SRTN = speech reception threshold in noise; IPD = interaural phase difference; BMR = binaural masking release; STM = spectrotemporal modulation; TiN = tone-in-noise; TMR = temporal masking release; SMR = spectral masking release.