Table 3.

Comparison among both 3D dosimetry methods (LDM and DPK) in terms of D5, D25, D50, D70, and D95 delivered to target normal liver, whole normal liver, and individual tumors: Bland Altman analysis and Lin concordance coefficients

Bland-Altman Correlation and concordance coefficients
∆D (Gy) Bias [95%CI] (Gy) Points beyond ± 2 SD (%) ρ ρc
Target normal liver
 D5 0.3 − 0.9; 0.4 7.1 0.999 0.999
 D25 − 0.2 − 0.8; 0.4 7.1 1.000 1.000
 D50 0.2 − 0.8; 1.1 0.0 1.000 1.000
 D70 0.4 − 1.0; 1.9 0.0 1.000 0.999
 D95 2.3 0.0; 5.9 7.1 1.000 0.996
Whole normal liver
 D5 0.1 − 0.4; 0.3 7.1 0.999 0.998
 D25 − 0.1 − 0.5; 0.2 7.1 1.000 1.000
 D50 − 0.1 − 0.9; 0.7 7.1 1.000 1.000
 D70 0.1 − 1.2; 1.3 0.0 1.000 1.000
 D95 2.5 0.1; 4.9 7.1 1.000 0.996
Individual tumors
 D5 − 0.3 − 1.6; 1.0 5.0 0.999 0.999
 D25 − 0.1 − 1.7; 1.8 4.0 0.999 0.999
 D50 0.4 − 1.7; 2.5 6.0 1.000 0.999
 D70 1.1 − 2.3; 4.5 4.0 1.000 0.999
 D95 3.1 − 9.0; 15.2 2.0 0.999 0.995