Skip to main content
. 2020 Dec 3;32(4):170–181. doi: 10.5371/hp.2020.32.4.170

Table 3. Type of Implants in Each Studies.

Study Type of implant Character Antirotational effect
Watson et al.7) (2016) CMN No blade type, 1 cephalomedullary screw
TasyIkan et al.9) (2015) PROFIN nails (TST Inc., Istanbul, Turkey) with 2 cephalomedullary screw No blade type, 2 cephalomedullary screw +
Hu et al.8) (2013) PFNA (DePuy Synthes, Solothurn, Switzerland) Blade type
Massoud3) (2010) Gamma nail or DHS or cancellous screws No blade type *
Su et al.11) (2006) DHS+antirotational cancellous screw No blade type +
Chen et al.1) (2008) DHS±antirotational cancellous screw No blade type ±
Saarenpää et al.10) (2002) DHS-antirotational cancellous screw No blade type
Kuokkanen13) (1991) DHS No blade type
Davis et al.12) (1990) DHS or γ-nail No blade type
Kweon et al.14) (2017) Gamma3 CMN (Stryker, Kalamazoo, MI, USA) No blade type +
Lee et al.15) (2018) DHS or PFNA (DePuy Synthes) Blade type in CMN group ±
Guo et al.16) (2019) PFNA (DePuy Synthes) Blade type +
Wang et al.17) (2019) PFNA (DePuy Synthes) Blade type +
Kim et al.18) (2020) DHS or CMN (Gamma-3 nail (Stryker, Kiel, Germany), Zimmer natural nail (Zimmer, Warsaw, IN, USA), ITST nail (Zimmer), PFNA (DePuy Synthes), InterTAN nail (Smith-Nephew, Memphis, TN, USA) Single screw type, blade type and two integrated screw type in CMN group ±
Yoo et al.19) (2019) ITST nail (Zimmer), PFNA (DePuy Synthes), Gamma 3 CMN (Stryker Trauma GmbH, Schoenkirchen, Germany) Single screw type, blade type ±

CMN: cephallomedullary nail, PFNA: proximal femoral nail-antirotation, DHS: dynamic hip screw, ITST: intertrochanteric/subtrochanteric.

*Cancellous screw was excluded in this review due to high failure rate.