Table 3: SARLE performance for the 427 chest CT test reports.

across the 9 labels with manually obtained ground truth. “# Pos” is the number of positive examples for that label in the report test set. F = equally weighted harmonic mean of precision and recall, P = Precision, R = Recall, Acc = Accuracy.

Label # Pos SARLE-Hybrid SARLE-Rules

F-score P R Acc F-score P R Acc
nodule 341 0.996 0.991 1 0.993 0.996 0.994 0.997 0.993
opacity 213 0.995 0.995 0.995 0.995 0.998 1 0.995 0.998
atelectasis 108 1 1 1 1 1 1 1 1
pleural effusion 88 0.978 0.967 0.989 0.991 0.977 0.988 0.966 0.991
consolidation 78 0.969 0.951 0.987 0.988 0.975 0.963 0.987 0.991
mass 55 0.915 0.857 0.982 0.977 0.956 0.931 0.982 0.988
pericardial effusion 44 0.755 0.685 0.841 0.944 0.956 0.935 0.977 0.991
cardiomegaly 34 0.919 0.850 1 0.986 0.986 0.971 1 0.998
pneumothorax 8 0.842 0.727 1 0.993 0.941 0.889 1 0.998