Skip to main content
. 2020 Nov 27;14:593806. doi: 10.3389/fnhum.2020.593806

Table 1.

Summary of stimulation thresholds for TMS and MPS.

REAL CONTROL P-values
Thresholds
RMT (%SO) 47.6 ± 6.2 48.0 ± 9.0 0.721
MT (mA) 74.2 ± 14.6 80.4 ± 11.7 0.215
Response latencies
MEP (ms) 32.8 ± 2.1 32.8 ± 1.8 1.00
F-wave (ms) 41.0 ± 4.4 40.6 ± 4.7 0.509
ISI (ms) 6.2 ± 3.1 22.8 ± 3.4 <0.001

Summary of MEP and F-wave latencies used to calculate individual ISI for each participant for each condition. Values are reported as mean ± SD. A paired t-test with a significance level of 0.05 was used to test for differences between the REAL and CONTROL condition values.