Skip to main content
. 2020 Dec 3;13(23):5509. doi: 10.3390/ma13235509

Table 2.

Shielding effectiveness of tested samples containing petroleum coke.

Graphite Content by Volume (%) Layer Thickness (mm) Shielding Effectiveness (dB)
1.0 GHz 1.5 GHz
0 4.36 4.00 2.42
0.51 4.38 43.5 44.6
1.02 4.41 47.3 49.2
3.06 4.35 48.2 50.2
6.12 4.66 49.3 51.6
9.18 4.77 49.7 51.9