Table. 1.

Overall Test Performance on the MoNuSeg Dataset.

Same organ test Different organ test
AJI Dice RQ SQ PQ AJI Dice RQ SQ PQ
FCN8 [5] 0.406 0.767 0.601 0.705 0.425 0.452 0.795 0.581 0.713 0.416
U-Net [6] 0.531 0.726 0.641 0.680 0.440 0.513 0.720 0.580 0.666 0.387
SegNet [7] 0.508 0.785 0.688 0.733 0.506 0.505 0.814 0.650 0.752 0.492
DCAN [9] 0.513 0.770 0.669 0.712 0.476 0.518 0.789 0.646 0.725 0.469
DIST[10] 0.563 0.786 0.747 0.757 0.566 0.593 0.825 0.708 0.780 0.554
HoVer-Net [22] 0.607 0.802 0.769 0.761 0.587 0.625 0.831 0.733 0.774 0.571
Ours 0.621 0.813 0.781 0.762 0.596 0.641 0.837 0.760 0.775 0.592