Table 1.
Conventional Bioptics | Reverse Bioptics | P value | |
---|---|---|---|
Number of eyes (patients) | 87 (49) | 13 (7) | – |
M/F (eyes) | 41:46 | 4:8 | – |
PRK/LASIK (eyes) | 61:26 | 2:11 | – |
Mean age (range) (y) | 33.1 (21 to 56) | 33.7 (21 to 45) | 0.82 |
Time between procedures (month)* | 3.8 ± 2.1 (1 to 10) | 2.67 ± 2.1 (1 to 7) | 0.07 |
UDVA* | 1.56 ± 0.32 (1.00 to 3.00) | 1.56 ± 0.12 (1.48 to 1.90) | 0.97 |
CDVA* | 0.03 ± 0.09 (0.00 to +0.40) | 0.11 ± 0.10 (0.00 to +0.30) | <0.01* |
SEQ (D)* | −11.12 ± 3.39 (−19.88 to −3.38) | −12.42 ± 1.81 (−15.38 to −9.13) | < 0.01* |
Refractive cylinder (D)* | −2.49 ± 1.16 (−6.00 to −0.50) | −3.88 ± 1.43 (−6.75 to −2.00) | < 0.01* |
Notes: Visual acuity reported as LogMAR. *Values reported as mean ± SD (range). Monovision eyes were excluded from UDVA analysis.
Abbreviations: UDVA, uncorrected distance visual acuity; CDVA, corrected distance visual acuity; SEQ, spherical equivalent refraction.