TABLE 2.
The k-fold cross-validation results of existed tools.
| Tools* | Fold | Accuracy | Sensitivity | Specificity | AUC |
| MDD-SOH | 5 | 0.68 | 0.7 | 0.7 | |
| SOHSite | 5 | 0.71 | 0.72 | 0.72 | |
| SOHPRED | 5 | 0.727 ± 0.005 | 0.742 ± 0.001 | 0.801 ± 0.001 | |
| iSulf-Cys | 10 | 0.656 ± 0.007 | 0.673 ± 0.007 | 0.639 ± 0.001 | 0.716 ± 0.009 |
| SulCysSite | 10 | 0.745 ± 0.006 | 0.744 ± 0.002 | 0.806 ± 0.002 | |
| Sulf_FSVM | 10 | 0.711 ± 0.002 | 0.733 ± 0.004 | 0.708 ± 0.002 | 0.788 ± 0.002 |
| LSTMWE | 10 | 0.739 ± 0.006 | 0.694 ± 0.042 | 0.744 ± 0.008 | 0.800 ± 0.011 |
| RFEAAC | 10 | 0.733 ± 0.006 | 0.607 ± 0.021 | 0.750 ± 0.007 | 0.753 ± 0.006 |
| RFE+S+A | 10 | 0.743 ± 0.009 | 0.728 ± 0.027 | 0.745 ± 0.009 | 0.807 ± 0.010 |
*The cross-validation dataset was derived from Yang’s publication (Yang et al., 2014).