Skip to main content
. Author manuscript; available in PMC: 2020 Dec 15.
Published in final edited form as: Clin Oral Investig. 2019 Mar 5;23(12):4255–4262. doi: 10.1007/s00784-019-02870-8

Table 1.

Pre- and postoperative parameters evaluated according to group

WaveOne Gold XP Shaper
Parameter Mean ± SD Median (range) Mean ± SD Median (range)
Preoperative
 Length (mm) 15.17 ± 1.68 15.50 (12.50–17.00) 15.28 ± 1.42 16.00 (12.00–16.50)
 Curvature angle 41.56 ± 13.07 43.00 (25.00–59.00) 40.78 ± 13.41 36.00 (29.00–69.00)
 Curvature radius 6.58 ± 1.21 6.88 (4.37–7.93) 6.26 ± 0.97 6.17 (4.87–8.00)
 Volume (mm3) 1.28 ± 0.54 1.12 (0.62–2.39) 1.76 ± 0.53 1.52 (1.32–2.53)
Postoperative
 Dentine removed (mm3) 2.53 ± 0.95 2.87 (0.76–3.39) 2.85 ± 0.94 2.68 (1.83–4.61)
 Debris remaining (mm3) 0.39 ± 0.51 0.12 (0.00–1.21) 0.16 ± 0.19 0.09 (0.02–0.58)
Unprepared area (%) 2.80 ± 2.98 1.29 (0.22–8.71) 2.45 ± 1.12 1.96 (0.82–4.27)

SD standard deviation

No statistically significant difference was found between groups (unpaired t test, P > 0.05)