Specimen no. Starting point from AC joint GTH (1) vs axillary nerve (mm) GTL (3) vs axillary nerve (mm) Calcar screw (4) vs axillary nerve (mm) Articular margin to lateral edge of insertion (mm) Maximal screw spread between LT and GTL (mm) Acromion to axillary nerve (mm) AP radiographic eval distance from medial GT to guide pin (mm) AP radiographic eval distance from lateral GT to guide pin (mm)
Medial specimens
 7: Right 64F 4 mm lateral 40 35 20 8 64 65 54 92
 2: Left 55F 0 mm 68 43 3 4 50 55 50 154
 3: Left 62M 0 mm 40 24 18 10 58 60 84 155
 4: Left 56F 2 mm medial 38 32 24 6 57 65 59 116
 5: Right 77M 5 mm lateral 50 38 24 6 59 60 80 162
Lateral specimens
 1: Left 64F 8 mm lateral 22 14 5 0 29 60 39 116
 6: Left 58F 20 mm lateral 21 9 10 2 48 62 17 60
 8: Right 72F 5 mm lateral 42 36 7 0 45 80 11 54
 9: Right 62F 35 mm lateral 40 26 15 0 35 54 -12 38
 10: Left 72F 25 mm lateral 25 20 4 5 47 50 23 77

AC, acromioclavicular; GTH, greater tuberosity high (screw); GTL, greater tuberosity low (screw); LT, lesser tuberosity; GT, greater tuberosity; AP, anteroposterior; eval, evaluation.

Negative measure indicates measurement in the medial direction.