Skip to main content
. 2020 Nov 16;12(11):e11497. doi: 10.7759/cureus.11497

Table 2. Pre- and post-TAVI echo parameters.

TAVI, transcatheter aortic valve implantation; AV, aortic valve; NYHA, New York Heart Association

  Pre-TAVI Post- TAVI* P-value
Valve Parameters
AV Mean Gradients (mmHg) 51.33 ± 10.47 5.33 ± 4.13 <0.001
AV Peak Gradients (mmHg) 81.48 ± 15.29 8.84 ± 4 <0.001
AV Area (cm2) 0.82 ± 0.18 2.75 ± 1.02 <0.001
New York Heart Association (NYHA) Functional Classification
NYHA I, II 11 [11%] 95 [95%] <0.001
NYHA III 69 [69%] 1 [1%]
NYHA IV 16 [16%] 0 [0%]
Not assessed/missing 4 [4%] 4 [4%]