Skip to main content
. 2020 Dec 17;6:27. doi: 10.1038/s41405-020-00056-z

Table 3.

The timing parameters.

The durations of the timing parameters are given in ms, and compared with ANOVA
AF-bites BF-bites
Parameter Mean(s.d.) Min–max Mean (±s.d) Min–max
FTt 67 (61) 2–332 24 (17) 2–71 a
t1t 52 (53) 0–231 43 (39) 0–154 N.S.
STt 113 (102) 6–605 74 (76) 2–357 N.S.
t10t 151 (124) 14–738 138 (116) 16–411 N.S.
tBt 385 (284) 56–1817 334 (238) 115–928 N.S.
t95t 640 (416) 118–2529 584 (462) 198–2497 N.S.

aSignificantly different as compared by one-way ANOVA [F(1, 272) = 6.91445, p = 0.009037].