RNFL (quality and thickness) P value comparing group meansa Mean (SD) [range]
Glaucoma (n = 15) Glaucoma suspect (n = 13) Neither (n = 44)
Image quality, 1-40 dB .77 28.0 (5.9) [20.0-40.0] 27.0 (6.9) [15.0-37.0] 26.7 (5.9) [14.0-37.0]
Overall, μm .08 93.3 (18.1) [55.0-128.0] 104.2 (12.7) [87.0-126.0] 103.5 (15.4) [63.0-145.0]
Nasal, μm .80 74.8 (18.4) [36.0-103.0] 76.4 (22.6) [45.0-113.0] 79.1 (20.4) [42.0-129.0]
Nasal inferior, μm .06 96.3 (27.5) [56.0-153.0] 105.7 (32.3) [55.0-161.0] 121.8 (41.1) [63.0-274.0]
Nasal superior, μm .36 100.1 (31.9) [39.0-159.0] 111.8 (29.8) [71.0-150.0] 113.2 (30.3) [56.0-195.0]
Temporal, μm .08 75.1 (16.6) [52.0-107.0] 87.8 (15.4) [68.0-115.0] 78.7 (14.9) [55.0-118.0]
Temporal inferior, μm .20 133.1 (33.1) [68.0-191.0] 147.5 (28.8) [66.0-192.0] 147.1 (23.5) [100.0-206.0]
Temporal superior, μm .08 117.2 (33.4) [43.0-177.0] 136.5 (23.3) [82.0-169.0] 134.1 (24.8) [83.0-187.0]

Abbreviation: RNFL, retinal nerve fiber layer.

a

For each RNFL measurement, a 1-way fixed-effects analysis of variance F test was performed to compare the 3 group means.