Skip to main content
. 2020 Dec 4;22(12):e21770. doi: 10.2196/21770

Table 1.

Analysis of rtCGM readings within the first 16 days of life in a neonate with transient CHI, including mean sensor glucose (SD), time in hypoglycemia (defined as the percentage of sensor readings below 45 mg/dL), and time in range (defined as the percentage of sensor readings between 45 mg/dL and 180 mg/dL).

Patient age, d (h) Sensor readings, n Glucose, mg/dL, mean (SD) Readings in range, n TIRa, % Readings in hypoglycemia, n TIHb, %
2 (39-48) 74 68 (16) 71 95.9 3 4.1
3 (49-72) 291 69 (29) 240 82.5 51 17.5
4 (73-96) 288 98 (34) 288 100.0 0 0.0
5 (97-120) 290 79 (16) 286 98.6 4 1.4
6 (121-144) 291 82 (17) 280 96.2 11 3.8
7 (145-168) 282 94 (36) 274 97.2 8 2.8
8 (169-192) 287 77 (21) 270 94.1 17 5.9
9 (193-216) 203 85 (29) 190 93.6 13 6.4
10 (217-240) 213 81 (22) 197 92.5 16 7.5
11 (241-264) 284 81 (25) 261 91.9 23 8.1
12 (265-288) 281 86 (24) 274 97.5 7 2.5
13 (289-312) 296 81 (19) 284 95.9 12 4.1
14 (313-336) 288 73 (20) 265 92.0 23 8.0
15 (337-360) 248 72 (18) 235 94.8 13 5.2
16 (361-372) 138 83 (17) 138 100.0 0 0.0

aTIR: time in range.

bTIH: time in hypoglycemia.