Skip to main content
. Author manuscript; available in PMC: 2021 Dec 1.
Published in final edited form as: IEEE Trans Med Imaging. 2020 Nov 30;39(12):4357–4368. doi: 10.1109/TMI.2020.3017450

TABLE II.

Functional performances of proposed OSSI prospectively undersampled reconstruction and standard GRE imaging

# Activated Voxels Average tSNR
2D 3D 2D 3D
OSSI 322 2150 32.8 34.7
GRE 83 947 9.8 15.9
Ratio 3.9 2.3 3.3 2.2