Skip to main content
. Author manuscript; available in PMC: 2021 Jan 1.
Published in final edited form as: Med Phys. 2019 Nov 19;47(1):260–266. doi: 10.1002/mp.13884

Table 1.

Dose enhancement factors as a function of radiation source and weight percent of gold.

% Gold by mass Radiation Source DEF
1.8 I-125 2.16
1.8 50 kVp 1.92
1.8 Yb-169 2.08
0.7 I-125 1.68
0.7 50 kVp 1.57
0.7 Yb-169 1.44
5.0 Ir-192 1.11