. 2020 Dec 28;17(12):766–774. doi: 10.11909/j.issn.1671-5411.2020.12.006

Table 2.

Follow-up Doppler echocardiographic data in the whole cohort, grouped by different methods.

Variable Post-TAVI P-value
Method 1 Method 2
Data are presented as means ± SD or n (%). EI: eccentricity index; EOA: effective orifice area; EOAI: indexed effective orifice area; LVOT: left ventricular outflow tract; LVOTd: left ventricular outflow tract diameter; PPM: prosthesis-patient mismatch; TAVI: transcatheter aortic valve implantation; VTILVOT: velocity-time integral of the left ventricular outflow tract.
LVOTd, cm 1.84 ± 0.21 1.64 ± 0.18 < 0.001
VTILVOT, cm 23.37 ± 5.34 27.47 ± 5.77 < 0.001
Velocity of LVOT, cm/s 118.56 ± 26.52 140.34 ± 24.51 < 0.001
EOA, cm2 1.56 ± 0.39 1.48 ± 0.41 0.001
EOAI, cm2/m2 0.93 ± 0.23 0.88 ± 0.24 0.001
EI 0.04 ± 0.05 0.11 ± 0.06 < 0.001
Moderate PPM 24 (21.2%) 33 (29.2%) 0.030
Sever PPM 14 (12.4%) 24 (21.2%) < 0.001