Table 2.
Follow-up Doppler echocardiographic data in the whole cohort, grouped by different methods.
| Variable | Post-TAVI | P-value | |
| Method 1 | Method 2 | ||
| Data are presented as means ± SD or n (%). EI: eccentricity index; EOA: effective orifice area; EOAI: indexed effective orifice area; LVOT: left ventricular outflow tract; LVOTd: left ventricular outflow tract diameter; PPM: prosthesis-patient mismatch; TAVI: transcatheter aortic valve implantation; VTILVOT: velocity-time integral of the left ventricular outflow tract. | |||
| LVOTd, cm | 1.84 ± 0.21 | 1.64 ± 0.18 | < 0.001 |
| VTILVOT, cm | 23.37 ± 5.34 | 27.47 ± 5.77 | < 0.001 |
| Velocity of LVOT, cm/s | 118.56 ± 26.52 | 140.34 ± 24.51 | < 0.001 |
| EOA, cm2 | 1.56 ± 0.39 | 1.48 ± 0.41 | 0.001 |
| EOAI, cm2/m2 | 0.93 ± 0.23 | 0.88 ± 0.24 | 0.001 |
| EI | 0.04 ± 0.05 | 0.11 ± 0.06 | < 0.001 |
| Moderate PPM | 24 (21.2%) | 33 (29.2%) | 0.030 |
| Sever PPM | 14 (12.4%) | 24 (21.2%) | < 0.001 |