Table 1.

Acquisition sequence parameters.

Sequence Parameters Scan duration
T2w Fast Spin Echo 2 × 03:12.0
TR=12 s
TE=156 ms
SENSE factor: axial=2.11, sagittal=2.58
Sagittal and axial slice stacks
In-plane resolution = 0.8 × 0.8 mm2
1.6 mm slice thickness overlapped by 0.8 mm
290 × 290 × 203 voxels
T1w Inversion Recovery Fast Spin Echo 2 × 05:45.2
TR=4795 ms
TI=1740 ms
TE=8.7 ms
SENSE factor: axial=2.26, sagittal=2.66
Resolution matched to T2w
290 × 290 × 203 voxels
Multiband EPI (func) Single-shot EPI 15:03.5
TE=38 ms
TR=392 ms
Flip angle=34°
MB factor=9x
2300 vol
2.15 mm isotropic
67 × 67 × 45 × 2300 voxels
Single-band EPI (sbref) Bandwidth matched readout to multiband EPI 00:19.4
TR=3871 ms
TE=38 ms
4 vol
67 × 67 × 51 voxels
Spin-echo EPI (field map) Bandwidth matched readout to multiband EPI 01:52.7
TR=8040 ms
TE=63 ms
4xAP/PA interleaved phase-encoding directions
67 × 67 × 51 × 8 voxels
Dual-echo-time (fieldmap) Dual-TE gradient-echo 00:20.2
TR=10 ms
TE1=4.6 ms; TE2=6.9 ms
flip angle=10°
3 mm isotropic in-plane resolution, 6 mm slice thickness
52 × 53 × 18 voxels