Skip to main content
letter
. 2020 Dec 11;20(24):7117. doi: 10.3390/s20247117

Table 11.

Comparison of error rates between LVDT and the four methodologies. Color display of error rate (Green: within 10%, Yellow: within 5%).

Case 8 mm 10 mm 12 mm
LVDT (mm) LVDT (mm) LVDT (mm)
Grid Tri LSP OSP Grid Tri LSP OSP Grid Tri LSP OSP
LC1 −4.41 −2.01 −1.19
40.8 40.8 32.0 9.5 91.5 88.1 69.7 45.3 110.1 110.1 97.5 84.9
LC2 −8.31 −4.06 −2.36
21.7 21.7 18.5 4.8 41.4 41.4 33.3 9.6 74.2 64.8 50.0 36.0
LC3 −12.29 −6.01 −3.53
10.8 10.8 6.7 3.7 23.0 23.0 16.8 8.3 55.2 53.5 44.8 21.5
LC4 −16.29 −8.11 −4.64
9.3 8.6 5.1 3.0 21.5 20.6 14.2 6.4 37.3 36.9 28.9 9.7