. 2020 Dec 21;20(24):7343. doi: 10.3390/s20247343

Table 1.

Performance comparison between the proposed filter and other fifth-order low-pass filters for ECG signal acquisition.

Symbol This Work MEJ (2019) [10] IEEE TBioCAS (2019) [9] IEEE TCAS-II (2018) [8] IEEE TBioCAS (2009) [7]
VDD [V] 0.5 0.25 1 1 1
Tech [um] 0.18 0.13 0.18 0.18 0.18
VTH [V] 0.5 0.44 0.5 0.5 0.5
Order (N) 5 5 5 5 5
No. of active device 5 MIGD-OTAs 6 FDDTAs 6 OTAs 6 OTAs 11 OTAs
Structure Gm-C fully-diff. Gm-C fully-diff. Gm-C fully-diff. Gm-C fully-diff. Gm-C fully-diff.
BW [Hz] 250 100 250 250 250
IRN [µVrms] 167 4.7 134 100 300
DR [dB] 63.24 57.00 61.2 49.9 50
Power (P) [nW] 34.65 603 41 350 453
FOM = P/(N * BW * DR) [pJ] 0.0191 1.7 0.0286 0.896 1.15
LV capability = VTH/VDD * 100 [%] 100 176 50 50 50
Area [mm2] 0.08 (estim.)
(off-chip cap.)
0.67
(off-chip cap.)
0.24 0.12 0.13
Obtained results Simulation Measured Measured Measured Measured