Kinetic parameters “E (kJ/mole) and A (1/s)” at two heating rates for switchgrass and switchgrass mixed with different catalysts.

Heating rate °C/min SG 30KP 30Clino 30Bento 10KP/10Clino 10KP/10Bento
First stage 25 (250–420°C) (D-2)
E = 106
A = 2.21E+06
R2 = 0.988
(F-1.5)
E = 59.7
A = 896
R2 = 0.975
(F-1)
E = 58.1
A = 377
R2 = 0.986
(F-1)
E = 63.1
A = 1002
R2 = 0.991
(F-1)
E = 61.8
A = 130
R2 = 0.975
(F-1)
E = 58.6
A = 395
R2 = 0.980
100 (280–450°C) (D-2)
E = 114
A = 1.01E+07
R2 = 0.989
(F-1.5)
E = 71.6
A = 18,806
R2 = 0.981
(F-1.5)
E = 77.3
A = 50,030
R2 = 0.986
(F-1.5)
E = 80.6
A = 89,531
R2 = 0.986
(F-1)
E = 69.1
A = 1,083
R2 = 0.976
(F-1)
E = 65.9
A = 3,846
R2 = 0.983
Second stage 25 (420–550°C) (F-1.5)
E = 45.9
A = 114
R2 = 0.999
(F-1.5)
E = 31.6
A = 2.60
R2 = 0.990
(F-1.5)
E = 23.1
A = 0.54
R2 = 0.999
(F-2)
E = 34.4
A = 10.69
R2 = 0.999
(F-1.5)
E = 29.6
A = 1.68
R2 = 0.992
(F-1.5)
E = 26.1
A = 0.88
R2 = 0.997
100 (450–550°C) (F-1.5)
E = 35.8
A = 23.7
R2 = 0.999
(F-2)
E = 22.4
A = 0.0001
R2 = 1
(F-1)
E = 28.6
A = 5.49
R2 = 0.999
(F-1)
E = 34.9
A = 19.5
R2 = 0.999
(F-1)
E = 16.9
A = 0.218
R2 = 0.993
(F-1)
E = 14.6
A = 0.137
R2 = 0.997