Representative works based on combined mechanisms

Materials Gas detection Detection range Work temperature Refs.
Co3O4/PEI-CNTs CO 5–1000 ppm RT [265]
HC(NH2)2SnI3/SnO2/Pt HCHO 5–100 ppm 80 °C [266]
PdO/SnO2/CuO CO 100–2000 ppm 200 °C [267]
Pd/ZnO/In2O3 H2 50–172 ppb 350 °C [268]
rGO/ZnO/Pd CH4 25–500 ppm RT [269]
Pt/ZnO/g-C3N4 Ethanol 0.5–50 ppm 250 °C [270]
NO2 0.5–15 ppm 150 °C
Au/Cu2O/ZnO NO2 5–1000 ppb RT [271]
Ag/SnO2/rGO Ethanol 100–2000 ppm 280 °C [272]
TiO2/InVO4 NH3 10–1000 ppm 250 °C [273]
Pd–SnO2/rGO CH4 800–1200 ppm RT [274]
Au@In2O3@PANI NH3 0.5–100 ppm RT [275]
Au–ZnO@ZIF-DMBIM Acetone 0.0001–1000 ppm RT [203]
SnO2/α-Fe2O3/Pt Styrene 0.25–1.25 ppm 206 °C [276]