Skip to main content
. 2020 Dec 16;5(4):e21551. doi: 10.2196/21551

Table 2.

Changes in hemoglobin A1c, weight, and blood glucose.

Measure Mean (SD) SE P value
Hemoglobin A1c(%)

Enrollmenta 5.9 (0.23) 0.06 N/Ab

Sensor 1c 5.2 (0.38) 0.10 N/A

Sensor 2c 5.2 (0.37) 0.10 N/A

Δd: Sensor 2—Enrollment –0.71 (0.46) 0.12 <.001

Δ: Sensor 2—Sensor 1 –0.01 (0.31) 0.08 .87
Weight (lbs)

Visit 1 (starting weight) 232.7 (45.1) 11.7 N/A

Visit 2 233.2 (46.2) 11.9 N/A

Visit 3 231.8 (45.9) 11.8 N/A

Δ: Visit 3—Visit 1 –0.89 (2.94) 0.76 .26

Δ: Visit 3—Visit 2 –1.41 (2.18) 0.56 .02
Average daily glucose (mg/dL)

Sensor 1 103.8 (10.6) 2.8 N/A

Sensor 2 102.9 (10.9) 2.9 N/A

Δ: Sensor 2—Sensor 1 –0.93 (8) 2.1 .67
Time spent in hyperglycemiae(%)

Sensor 1 7.1 (7.9) 2.1 N/A

Sensor 2 4.5 (5.6) 1.5 N/A

Δ: Sensor 2—Sensor 1 –2.6 (6.5) 1.7 .16

aMeasured hemoglobin A1c (HbA1c) by clinical laboratory.

bN/A: not applicable.

cHbA1c estimated from continuous glucose monitor data.

dDelta or difference.

eGlucose >140 mg/dL.