Skip to main content
. 2019 Nov 14;10(6):571–580. doi: 10.1016/j.jpha.2019.11.004

Table 2.

The regression equations, linear ranges and LLOQs for the determination of the analytes in rat plasma.

Compounds Regression equation R Linear range (ng/mL) LLOQ (ng/mL)
Shanzhiside Y = 0.42X−0.0055 0.997 10–200 10
Genipin-1-gentiobiosode Y = 0.78X+0.0051 0.999 1–1000 1
Geniposide Y = 9.31X+0.69 0.998 1–4000 1
Genipin Y = 1.38X+0.024 0.999 1–2000 1