Skip to main content
. 2021 Jan 1;12(3):754–764. doi: 10.7150/jca.52797

Table 1.

Description of Included Studies

Study Year Country Age (y) Sample size Design Patient recruitment Blind to reference Magnetic field Manufacturer Sequences Depth of cervical invasion
Morimura 2000 Japan U 47 R U U U U T2 Any cervix
Seki 2000 Japan U 39 P U Yes 1.5T Siemens DCE Any cervix
Cunha 2001 Portugal 63.2 40 P U Yes 1.0T Philips T2+DCE Any cervix
Manfredi 2004 Italy 58.8 37 P C Yes 1.5T GE T2 Any cervix
Akaeda 2005 Japan 56.8 21 P U Yes 1.5T Siemens CO2-VIBE Any cervix
Haider 2006 Canada 56 38 R U Yes 1.5T GE T2 Any cervix
Nagar 2006 UK 65.5 135 R C Yes 1.5T Siemens T2 Stroma
Rockall 2007 UK 61 84 R U Yes 1.5T GE DCE Stroma
Vasconcelos 2007 Portugal 68.5 101 P U Yes 1.0T Philips T2+DCE Any cervix
Cabrita 2008 Portugal 64.6 162 U U U 1.5T U U Any cervix
Cicinelli 2008 Italy 67.3 100 U C Yes 1.5T Philips T2 Any cervix
Sanjuan 2008 Spain U 72 R C U 1.0T Siemens T2+DCE Any cervix
Savelli 2008 Italy 63 74 P C Yes U U T2 Any cervix
Hori 2009 Japan 58.7 30 P C Yes 3.0T GE T2 Any cervix
Undurraga 2009 Switzerland 69.5 108 R C Yes 1.5T U T2+CE Stroma
Celik 2010 Turkey 58.9 64 P C Yes 1.5T Siemens U Any cervix
Emlik 2010 Turkey U 53 P C Yes 1.5T Siemens DCE Any cervix
Duncan 2012 UK U 748 U U U U U U Stroma
Haldorsen 2012 Norway 66 146 P U Yes 1.5T Siemens U Stroma
Tong 2012 China 52 168 R C U 1.5T GE T2+DCE Stroma
Zamani 2012 Iran 53.3 54 U U Yes 1.5T U U Stroma
Aly 2013 Egypt 59 40 U U Yes 1.5T GE DCE Stroma
Antonsen 2013 Denmark 65 226 P C Yes 1.5T Philips U Any cervix
Foti 2013 Italy 62 20 P C Yes 1.5T GE T2 Any cervix
Hahn 2013 Korea 53.1 131 R U Yes 1.5T Philips U Stroma
Hori 2013 Japan 57.6 71 P C Yes 3.0T Philips T2+DWI Stroma
Kitajima 2013 Japan 62.4 30 R U Yes 1.5T GE U Stroma
Gitte 2013 Denmark U 143 P U Yes 1.5T GE U Any cervix
Koplay 2014 Turkey 58 58 P C Yes 1.5T Siemens DWI Any cervix
Teng 2015 China 57.9 167 R U Yes 1.5T GE T2+DCE Any cervix
Yin 2015 China 54.6 98 R U Yes 3.0T U T2+DCE Any cervix
Zamani 2015 Iran U 68 P U Yes U U U Stroma
Angioli 2016 Italy 53 41 P U Yes 1.5T GE DWI Any cervix
Chan 2016 China 55.2 90 R U Yes 1.5T Siemens T2+DCE Stroma
Shrivastava 2016 India 52.8 36 R U Yes 1.5T Philips U Stroma
Lin 2017 China 56 83 U C Yes 3.0T Siemens DWI Stroma
Rahmani 2018 Iran U 27 P U Yes 3.0T Siemens U Any cervix
Xu 2018 China 51.89 88 R U U U U U Any cervix
Yildirim 2018 Turkey 61.1 40 P U Yes 1.5T Philips U Any cervix
Ytre-Hauge 2018 Norway 67 178 P C Yes 1.5T Siemens U Stroma
Goel 2019 India 60.2 58 P U Yes 1.5T GE T2+DCE Any cervix
Yang 2019 China 54.1 182 R U Yes 3.0T GE T2 Any cervix

U, unknown; P, prospective; R, retrospective; C, consecutive; CE, contrast-enhanced MRI; DCE, dynamic contrast-enhanced MRI; DWI, diffusion weighted imaging; CO2-VIBE, CO2-volumetric interpolated breathhold examination.