Skip to main content
. 2020 Dec 11;11(1):43–59. doi: 10.1021/acscatal.0c04290

Table 3. Summary of Weight Fractions Extracted from PXRD Patterns by Rietveld Refinement for All Initial Samples, as well as for the Recovered Ones after the In Situ PXRD Experiments and after the DRM Treatment.

sample/weight fraction (%) LaNi2O4 La2O3 La(OH)3 La2O2CO3 hex. La2O2CO3 mono. Ni metal BaCO3
La2Ni0.9Cu0.1O4 initial 98.9(0.9) 0.2(0.1) 0.9(0.3) - - - -
recovered from in situ experiment 99.2(0.8) 0.2(0.2) - - 0.6(0.2) - -
recovered from DRM experiment - 63.2(1.6) 10.8(0.8) - 10.7(1.0) 15.3(1.2) -
La2Ni0.8Cu0.2O4 initial 98.6(0.8) 0.5(0.2) 0.9(0.2) - - - -
recovered from in situ experiment - 73.3(0.8) - 1.3(0.3) 5.8(0.7) 19.6(0.7) -
recovered from DRM experiment - 56.7(0.9) 24.4(0.7) - 1.8(0.3) 17.1(0.3) -
La1.8Ba0.2NiO4 initial 97.3(1.3) 1.8(0.2) 0.9(0.2) - - - -
recovered from in situ experiment 97.7(1.4) 0.9(0.2) - 0.7(0.2) 0.5(0.2) 0.2(0.1) -
recovered from DRM experiment - 65.6(0.9) - - 11.9(0.6) 16.4(0.6) 6.1(0.4)
La1.8Ba0.2Ni0.9Cu0.1O4 initial 98.6(0.6) 0.8(0.1) 0.6(0.1) - - - -
recovered from in situ experiment - 28.6(0.5) - 13.6(0.4) 40.0(0.7) 17.8(0.5) -
recovered from DRM experiment - 65.4(0.9) - - 12.0(0.6) 17.4(0.6) 5.2(0.4)