Fig. 11.
Transient cavitation analysis for Mg suspensions in ethylene glycol–water mixtures measured by hydrophone located under the sonotrode: a) pure ethanol, b) 20 vol% ethylene glycol – 80 vol% water, c) 50 vol% ethylene glycol – 50 vol% water, d) 80 vol% ethylene glycol – 20 vol% water. Insets correspond to the measurements in the liquids without particles. The concentration of Mg particles comprised 0.003 g/mL in all experiments.