Skip to main content
. 2020 Jul 6;107(2):142–149. doi: 10.1136/heartjnl-2020-316613

Table 3.

Effect of external ventilation in Fontan subjects and controls

CMR flows
Δ flow (L/min/m2)
Fontan subjects (n=10) Controls
(n=10)
P value
Effect of NPV
 SVC 0.00 (−0.02–0.07) 0.04 (−0.31–0.23) 0.571
 Fontan/Sup-IVC 0.16 (0.11–0.35) −0.21 (0.48–0.05) 0.004
 Sub-IVC 0.14 (−0.02–0.26) 0.01 (−0.21–0.30) 0.472
 HV 0.14 (0.01–0.30) −0.21 (−0.38–−0.01) 0.026
 PoV 0.07 (−0.01–0.14) 0.02 (−0.04–0.10) 0.345
 PBF 0.20 (0.10–0.53) −0.09 (−0.43–0.09) 0.009
 CO 0.17 (−0.11–0.23) 0.07 (−0.31–0.23) 0.571
Effect of BPV
 SVC 0.08 (−0.01–0.19) 0.02 (−0.16–0.09) 0.089
 Fontan/Sup-IVC 0.58 (0.09–0.81) 0.00 (−0.50–0.15) 0.009
 Sub-IVC 0.22 (0.04–0.58) −0.01 (−0.26–0.30) 0.111
 HV 0.26 (0.04–0.58) −0.03 (−0.12–0.05) 0.045
 PoV 0.05 (−0.05–0.10) −0.04 (−0.12–0.02) 0.088
 PBF 0.61 (0.20–0.84) −0.27 (−0.55–0.13) 0.001
 CO 0.47 (0.21–0.71) 0.07 (−0.47–0.33) 0.034

Data expressed as median (IQR).

BPV, biphasic ventilation; CMR, cardiovascular magnetic resonance; CO, cardiac output; HV, hepatic vein; NPV, negative pressure ventilation; PBF, pulmonary blood flow; PoV, portal vein; Sub-IVC, subhepatic inferior vena cava; Sup-IVC, suprahepatic inferior vena cava; SVC, superior vena cava.