Table 2.

Aerosol-suppressing equipment and corresponding air/water flow rates. Low-volume suction was used in all intervention groups. In this study, the air cleaning system flow rate was equivalent to approximately 24 air changes per hour

Intervention Equipment Water flow (L min-1) Air flow (L min-1) Air changes per hour (in a 35 m3 surgery)
Low-volume suction Plastcare USA, 4 mm slow-speed salivary ejector 2.4 79 -
High-volume suction (intraoral) Dürr Universal Cannula III 16 mm, connected to Dürr Dental VSA 300S Dürr Dental UK, Kettering, UK - 297 -
High-volume suction (extraoral) Eighteeth VacStation,* Sifary Medical Technology, Jiangsu, China - 3,700 6
Air cleaning system Woodpecker Q7 Plasma Air Purifier,** Guilin Woodpecker Medical Instrument Co, Guilin, China - 14,167 24

Key:

* = the VacStation contains two H13-grade HEPA filters (lower particle size limit 0.3 μm) with a post-filter UVC light sterilisation stage

** = the Q7 air cleaning system is a filterless instrument which operates on a high-voltage plasma purification process with integral ion chamber sterilisation stage; the lower particle size limit is reportedly 14.6 nm