Skip to main content
. 2020 Sep 24;129(6):1441–1450. doi: 10.1152/japplphysiol.00253.2020

Table 2.

Grouped data for timing, ventilation, and resistance during the control periods of all BPPV trials on room air and oxygen, n = 10

Variables Room air Oxygen P Value
TI, s 2.2 ± 0.2 2.2 ± 0.2 ns
TE, s 2.1 ± 0.5 2.3 ± 0.2 ns
TTOT, s 4.3 ± 0.3 4.4 ± 0.2 ns
TI/TTOT 0.8 ± 0.3 0.7 ± 0.2 ns
fR, breath/min 14.4 ± 0.8 14.2 ± 0.8 ns
VT, L 0.6 ± 0.0 0.6 ± 0.0 ns
VE, L/min 7.8 ± 0.4 8.1 ± 0.6 ns
PETCO2, mmHg 38.3 ± 0.9 37.9 ± 0.8 ns
PETO2, mmHg 97.2 ± 1.5 277.6 ± 7.8 0.004
FIO2 0.48 ± 0.01 0.21 ± 0.00 <0.001
SaO2, % 95.7 ± 0.8 98.3 ± 0.3 0.002
Eupneic inspiratory RUA (cmH2O/L/s (n = 8) 5.4 ± 0.8 5.9 ± 0.9 ns

Results are means ± SE. TI, inspiratory time; TE, expiratory time; TTOT, total time of respiratory cycle; fR, respiratory frequency; VE, minute ventilation; FIO2, fraction of inspired O2; PETCO2, end-tidal carbon dioxide; PETO2, end-tidal oxygen; RUA, inspiratory resistance; SaO2, arterial O2 saturation; TE, expiratory time; VT, tidal volume.