Skip to main content
. Author manuscript; available in PMC: 2021 Jan 9.
Published in final edited form as: Int J Infect Dis. 2020 Oct 29;102:440–445. doi: 10.1016/j.ijid.2020.10.082

Table 3.

Results of the RT-LAMP assay for the detection of HCV on a panel of known HCV viral loads.

HCV viral load (IU/mL) All
Genotype 1
Genotype 3
Genotype 6
N n % N n % N n % N n %

7.01–8.00 log10 23 23 100 10 10 100 7 7 100 6 6 100
6.01–7.00 log10 96 96 100 39 39 100 33 33 100 24 24 100
5.01–6.00 log10 47 47 100 18 18 100 21 21 100 7 7 100
4.01–5.00 log10 28 23 82.1 12 10 83.3 14 11 78.6 2 2 100
3.01–4.00 log10 6 2 33.3 2 2 100 4 0 0
Total 200 191 95.5 81 79 97.5 79 72 91.1 39 39 100

HCV, hepatitis C virus; RT-LAMP, reverse transcription loop-mediated isothermal amplification assay.