General Properties of Mechanonociceptor Fibers Recorded From Intact and Injured Corneas at Different Times After Lesion With a Microkeratome

Injured Corneas (Time After Lesion)
Mechanonociceptors Intact Corneas 3–8 h 24–48 h 72 h 6–15 Days
Spontaneous activity (imp/s) 0.008 ± 0.004 (4/225) 0.022 ± 0.022 (1/25) 0 ± 0 (0/48) 0 ± 0 (0/29) 0 ± 0 (0/28)
Mechanical threshold (mN) 0.66 ± 0.005 0.50 ± 0.09 0.35 ± 0.02* 0.60 ± 0.14 0.57 ± 0.11
n 242 25 48 29 28