Comparison between the results of the BFCN and other methods on the DRIVE dataset.

Method Year Sensitivity Specificity Accuracy F-measure
Singh and Srivastava [8] 2016 0.7594 0.9723 0.947
Zhang et al. [10] 2015 0.7812 0.9668 0.9504
Lázár and Hajdu [38] 2015 0.7646 0.9723 0.9458
Zhao et al. [39] 2017 0.782 0.979 0.957
Zhang et al. [40] 2017 0.7861 0.9712 0.9527 0.7953
Yan et al. [41] 2018 0.8282 0.9738 0.9609
Alom [42] 2018 0.7792 0.9813 0.9556 0.8171
Zhuang [43] 2018 0.7856 0.9810 0.9560 0.8202
Wang et al. [44] 2019 0.7940 0.9816 0.9567 0.8270
Samuel and Veeramalai [21] 2019 0.8282 0.9738 0.9609
Ours 2019 0.8124 0.9822 0.9627 0.8294