Skip to main content
. 2020 Dec 28;72:105447. doi: 10.1016/j.ultsonch.2020.105447

Table 1.

The effect of ultrasonication on light transmittance of the films.

Film type Light transmission (%)
400-nm wavelength 500-nm wavelength 600-nm wavelength 700-nm wavelength 800-nm wavelength
Native sample 45.9 ± 0.99c 49.0 ± 0.74d 51.0 ± 1.19e 52.8 ± 1.23d 54.5 ± 1.15d
Control 17.3 ± 0.74e 17.6 ± 0.70f 18.2 ± 0.83 g 18.5 ± 0.77f 18.9 ± 0.88f
ST-LPD 42.0 ± 1.08d 44.5 ± 1.12e 47.0 ± 0.66f 48.4 ± 0.58e 49.7 ± 0.61e
MT-LPD 49.2 ± 1.00b 52.5 ± 0.99c 54.8 ± 0.69 cd 56.6 ± 1.15c 58.0 ± 1.35c
LT-LPD 50.2 ± 1.28b 52.9 ± 1.20c 55.0 ± 0.96c 56.4 ± 0.88c 57.6 ± 0.87c
ST-HPD 47.5 ± 1.05bc 50.2 ± 1.08 cd 52.1 ± 1.26de 53.4 ± 0.64d 55.2 ± 1.38 cd
MT-HPD 54.3 ± 0.99a 56.9 ± 0.89b 58.8 ± 1.02b 60.0 ± 0.81b 61.2 ± 0.78b
LT-HPD 57.0 ± 1.06a 59.9 ± 0.90a 62.2 ± 1.12a 63.6 ± 0.99a 64.7 ± 0.94a

a – g: Mean values in the same column with different superscripts are significantly different (P<0.05). Data shown in mean ± standard deviation (n = 3).