. 2020 May 25;14:24–31. doi: 10.1016/j.phro.2020.04.002

Table 1.

Overview of the image comparison. Image comparison calculated as mean (±1σ) and range ([min;max]) of the test dataset (30 patients; 10 patients for each treatment site) compared to the reference dataset in terms of mean absolute error (MAE) and mean error (ME) between the test (Test) image minus the reference (Ref) image.

Site Head-and-Neck Lung Breast
Test Ref MAE ME MAE ME MAE ME
[HU] [HU] [HU] [HU] [HU] [HU]
CBCT rCT 195 ± 20 [160;230] −122 ± 33 [−183;−71] 219 ± 44 [133;280] 153 ± 48 [94;230] 152 ± 40 [98;213] 71 ± 37[7;115]
sCT single networka rCT 53 ± 12 [37;77] −3 ± 7 [−15;10] 83 ± 10 [72;104] −2 ± 11 [−25;10] 66 ± 18 [41;95] −6 ± 13[−24;13]
sCT separate networksb rCT 51 ± 12 [35;74] −6 ± 6 [−16;4] 86 ± 9 [73;105] −5 ± 14 [−28;10] 67 ± 18 [41;98] −5 ± 11[−18;14]
CT rCT 63 ± 17 [−40;90] −18 ± 15 [−46;3] 94 ± 23 [68;146] 9 ± 22 [−33;36] 63 ± 24 [40;115] 8 ± 20[−14;54]

a sCT obtained from a single network trained on all the anatomical sites.

b sCT obtained from three different networks trained on each anatomical site.